Product Category
    Indoor VCB
Contact Us
Address:XiangYang Industrial Zone, Liushi town, Yueqing city Zhejiang Province
TEL:86-577-5688668
FAX:86-577-5688669
Mobile:
Email:sales@chinarenelectric.com ; tech@chinarenelectric.com
 
 Switch Disconnector Home >> Switch Disconnector 
GW4 Disconnector

Description:

GW4  3-phase switch disconnctor.
Rated current:630A 
Rated voltage:40.5KV 
ISO9001:2008 certificate

Main features:

1.Complete in specifications,high technical parameters is high, wide range. Additional, wide scope    of application , it can be used for high layout. Installation way is flexible. 

2.Perfect sealing Performance and  Resistant To Rust 

3.Simple, reliable mechanical rotating way. 

4.Perfect dustproof, waterproof, and anti-corrosion ability. 

5.Full set of steel galvanized foundation frame and the vertical and horizontal  dwang for option.


Technical data:


Technical Specifications   GW4-40.5 GW4-72.5 GW4-126
Rated voltage kV   40.5 72.5 126
The rated current A   1250, 2000
Disconnector Rated peak withstand current kA 100
Rated short-time withstand current (RMS)kA 40
Rated short circuit duration s 4
Grounding switch Rated peak withstand current kA 100
Rated short-time withstand current (RMS)kA 40
Rated short circuit duration s 4
Rated short-time power frequency withstand voltage (RMS) kV to earth 95 160 230
across isolating point 118 200 230+70
Rated lightning impulse withstand voltage (peak) kV to earth 185 350 550
across isolating point 215 410 550+100
minimum clearance in 1 min power frequency withstand voltage when ground blade closing to live part of disconnector   53 94 164
switching ability of earthing switch inductance current electromagnetic inductance current (current/voltage) 50/0.5(A type), 100/6(B type)
Static inductance current (current/voltage) 0.4/3(A type), 5/6(B type)
switching times 10 10 10
rated terminal static mechanic load N longitudinal level 1000 1000 1000, 1250
Horizontal level 750 750 750
Vertical force 1000 1000 1000
switching capacitance current A   2 2 2
switching inductance current A   1 1 1
switching busbar for current transfer A (busbar transfer voltage 100V)   400V, 2500A, 100 times
Radio interference level   less than 500 μV
Mechanical life   3000 3000 3000
single pole weight (kg)   240 300 350
note: All applied in an altitude of 2000m
 
 
Vacuum Load Breaker
SF6 Load Breaker
RTS load breaker
FKW18 Load Breaker
ZN63 (VS1) VCB
ZN63 Side-mounted VC
ZN63-24 VCB
ZN12 VCB
ZN85-40.5 Vacuum Bre
Disconnector GW9
Switch disconnector(
Switch disconnector
 
ChinaRen Electric Co.,Ltd. Add:XiangYang Industrial Zone, Liushi town, Yueqing city Zhejiang Province
E-mail:sales@chinarenelectric.com ; tech@chinarenelectric.com
Tel:86-577-5688668 Fax:86-577-5688669